Inclusive® Titanium Abutment Blank compatible with: CONELOG® Ø3.8/4.3 mm
Product Description
Inclusive® Titanium Abutment Blanks are designed to be used for the production of custom titanium abutments. All digitally designed abutments for use with Inclusive® Titanium Abutments for CAD/CAM are intended to be sent to a Prismatik Dentalcraft validated milling center for manufacture.
Accessories
None
Design Parameters
Inclusive® Abutments
- Minimum wall thickness is no less than 0.5 mm.
- Gingival margin diameter is no less than 0.5 mm wider than implant.
- Maximum gingival height is no greater than 6 mm.
- Maximum angle correction is no greater than 30 degrees.
- Minimum margin height is no less than 0.5 mm.
- Minimum post height above the gingival collar is no less than 4.0 mm.
Sterility
Inclusive® Titanium Abutment Blanks are shipped NON-STERILE. Non-sterile abutments and screws must be cleaned and sterilized prior to clinical use, according to a validated method.
- Cleaning: Prepare cleaning solution using 5 mL of dish soap per gallon of tap water. Fully immerse the devices in solution and scrub them with a soft-bristle brush. Remove the components and rinse them under running tap water. Dry the devices with a clean, lint-free cloth.
- Sterilization of Inclusive Titanium Abutments: Gravity-fed sterilizers: Autoclave in sterilization pouch for 30 minutes at 121 °C (250 °F). Devices are to be used immediately after sterilization.
NOTE: The validated procedures require the use of FDA-cleared sterilization trays, wraps, biological indicators, chemical indicators, and other sterilization accessories labeled for the sterilization cycle recommended. The healthcare facility should monitor the sterilizer for the facility according to an FDA- recognized sterility assurance standard such as ANSI/AAMI ST79.
Technical Specifications
Platform: Ø3.2 mm Ø3.6 mm
Material Composition: Titanium alloy (Ti6Al4V)
Original: $34.00
-65%$34.00
$11.90Product Information
Product Information
Shipping & Returns
Shipping & Returns
Description
Product Description
Inclusive® Titanium Abutment Blanks are designed to be used for the production of custom titanium abutments. All digitally designed abutments for use with Inclusive® Titanium Abutments for CAD/CAM are intended to be sent to a Prismatik Dentalcraft validated milling center for manufacture.
Accessories
None
Design Parameters
Inclusive® Abutments
- Minimum wall thickness is no less than 0.5 mm.
- Gingival margin diameter is no less than 0.5 mm wider than implant.
- Maximum gingival height is no greater than 6 mm.
- Maximum angle correction is no greater than 30 degrees.
- Minimum margin height is no less than 0.5 mm.
- Minimum post height above the gingival collar is no less than 4.0 mm.
Sterility
Inclusive® Titanium Abutment Blanks are shipped NON-STERILE. Non-sterile abutments and screws must be cleaned and sterilized prior to clinical use, according to a validated method.
- Cleaning: Prepare cleaning solution using 5 mL of dish soap per gallon of tap water. Fully immerse the devices in solution and scrub them with a soft-bristle brush. Remove the components and rinse them under running tap water. Dry the devices with a clean, lint-free cloth.
- Sterilization of Inclusive Titanium Abutments: Gravity-fed sterilizers: Autoclave in sterilization pouch for 30 minutes at 121 °C (250 °F). Devices are to be used immediately after sterilization.
NOTE: The validated procedures require the use of FDA-cleared sterilization trays, wraps, biological indicators, chemical indicators, and other sterilization accessories labeled for the sterilization cycle recommended. The healthcare facility should monitor the sterilizer for the facility according to an FDA- recognized sterility assurance standard such as ANSI/AAMI ST79.
Technical Specifications
Platform: Ø3.2 mm Ø3.6 mm
Material Composition: Titanium alloy (Ti6Al4V)